wenilandClaude Opus 4.8 8d82beaacf v2 Phase 1: verify FT3168 touch needs no coordinate transform
On-hardware calibration (5-point corner+center tap) confirms the FT3168 on the
2.06 panel reports directly in panel pixel space (~0..409 x ~0..501), correctly
oriented with no axis swap or mirror — a center tap reads ~(209,228) against the
410x502 panel center (205,251), a 1:1 mapping within finger error. The existing
raw passthrough is correct; record the verified result in the driver comment.
The temporary on-screen TOUCH_DEBUG overlay used to gather this has been removed.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-20 14:16:00 +03:00
..